I. Features:
The elastomer is made of alloy steel and is electroplated; the strain gauge material is imported from the United States and Japan, and it is potted and sealed. It is suitable for a variety of working environments, with simple structure and easy installation; Suitable for rotating equipment such as electric motors, internal combustion engines and torque testing equipment; range: 5-1000NM.
Two, wiring method
Three, technical parameters
Sensor range | NM | 5-1000 |
Accuracy class | C2 | |
Composite error | FS | ±0.1% |
Sensitivity | MV/V | 2.0±0.2 |
Zero output | FS | ±2% |
Creep | %FS/30MIN | ±0.03 |
Zero point temperature effect | %FS/10℃ | ±0.03 |
Sensitivity temperature effect | %FS/10℃ | ±0.03 |
input resistance | Ω | 350±5 |
Output impedance | Ω | 405±10 |
Insulation resistance | MΩ | ≥5000(100V) |
Temperature compensation range | °C | -10-40 |
Operating temperature range | °C | -35-65 |
Excitation voltage | V | 5-12 (DC) |
Safe overload range | % | 150 |
Protection level | IP65 | |
wire | M | 1.5m Φ5 shielded wire |